Filter control with differential pressure controlled compressed-air cleaning function for ATEX-zones 22 (3D) and 21 (2D).
Setting codes for the digital display: | |
---|---|
L1 | Hour counter |
L2 | Cycle counter |
P1 | Break time between valve activation |
P2 | Valve opening times |
P3 | After-cleaning time or cycles |
P4 | After-cleaning activation |
P5 | Measuring device |
P6 | Function for after-cleaning |
P7 | Operation hours / differential pressure operation |
P8 | Activation of cleaning |
P9 | Stop of cleaning |
P10 | Activation of after-cleaning |
P11 | Activation of relay 1 |
P12 | Parameter for dust build-up |
P13 | Value for dust build-up |
P16 | Selection of function in relay 1 |
P17 | Function for relay 1 |
P18 | Value for the function in relay 1 |
P19 | Break time between valve activation valid for after-cleaning |
H0 | 0-Calibration of the differential pressure sensor |
Zone 22:
II 3D Ex tc IIIB T90°C IP66 Dc
Zone21:
II 2D Ex tb IIIC T100°C Db IP66
Technical Data: | |
---|---|
Power supply: | 115VAC & 230VAC 50/60Hz |
Power consumption: | 50W (2 amp.) |
Output voltage: | 24-115-230VAC / 24 VDC |
Temperature range: | -10 + +50°C |
Visual indicators: | 10,000Pa |
Setting: | Keyboard |
Protection class / housing: | IP66 |
dP control: | Internal dP sensor |
Terminals: | 2.5mm² 250VAC/12A |
Weight: | 1.5kg (22) / 6.1kg (21) |